Apex Petrochemical Complex
Sensor specifications
Monitored parameters across the plant. Units and severity bands are defined once in the digital twin and must be reused by future AI and UI phases.
Gas (H₂S)
Unit: ppm
Fixed-point electrochemical or IR H₂S detectors at breathing height and high points.
Gas (H₂S)
Unit: ppm
Why monitored
Typical causes
- Flange / packing leaks
- Knockout drum overfill
- Relief valve lift
- Sampling station left open
Operating ranges
| Band | Range | Label |
|---|---|---|
normal | 0–10 ppm | Normal |
warning | 10–25 ppm | Warning |
danger | 25–45 ppm | Danger |
critical | ≥ 45 ppm | Critical |
Spec id: gas_h2s
Temperature
Unit: °C
RTD / thermocouple process and ambient temperature points.
Temperature
Unit: °C
Why monitored
Typical causes
- Catalytic runaway
- Cooling failure
- Steam leak
- External fire exposure
Operating ranges
| Band | Range | Label |
|---|---|---|
normal | 0–120 °C | Normal |
warning | 120–180 °C | Warning |
danger | 180–250 °C | Danger |
critical | ≥ 250 °C | Critical |
Spec id: temperature
Pressure
Unit: bar(g)
Gauge pressure on vessels, headers, and compressor discharge.
Pressure
Unit: bar(g)
Why monitored
Typical causes
- Blocked outlet
- PSV failure
- Compressor surge
- Line rupture
Operating ranges
| Band | Range | Label |
|---|---|---|
normal | 0–15 bar(g) | Normal |
warning | 15–28 bar(g) | Warning |
danger | 28–40 bar(g) | Danger |
critical | ≥ 40 bar(g) | Critical |
Spec id: pressure
Smoke
Unit: % obscuration / m
Optical smoke and aspirating detection near boilers, MCC, and loading canopies.
Smoke
Unit: % obscuration / m
Why monitored
Typical causes
- Incipient fire
- Insulation smolder
- Vehicle exhaust under canopy
Operating ranges
| Band | Range | Label |
|---|---|---|
normal | 0–5 % obscuration / m | Normal |
warning | 5–15 % obscuration / m | Warning |
danger | 15–35 % obscuration / m | Danger |
critical | ≥ 35 % obscuration / m | Critical |
Spec id: smoke
Worker Presence
Unit: persons
Badge / computer-vision headcount fused with zone access control.
Worker Presence
Unit: persons
Why monitored
Typical causes
- Turnaround surge
- Permit work
- Evacuation incomplete
Operating ranges
| Band | Range | Label |
|---|---|---|
normal | 0–8 persons | Normal |
warning | 8–15 persons | Warning |
danger | 15–25 persons | Danger |
critical | ≥ 25 persons | Critical |
Spec id: worker_presence
Permit Status
Unit: state
Electronic permit-to-work validity (hot work, confined space, LOTO).
Permit Status
Unit: state
Why monitored
Typical causes
- Expired permit
- Scope change
- Missing gas test
Operating ranges
| Band | Range | Label |
|---|---|---|
normal | 1–1 state | Valid |
warning | 0–0 state | Expiring / review |
danger | -1–-1 state | Invalid |
critical | -2–-2 state | Required but missing |
Spec id: permit_status
PPE Compliance
Unit: % compliant
Camera / gate checks for hard hat, H₂S monitor, FR clothing, and eye protection.
PPE Compliance
Unit: % compliant
Why monitored
Typical causes
- Missing personal H₂S monitor
- Incorrect FR layer
- Bypassed gate
Operating ranges
| Band | Range | Label |
|---|---|---|
normal | 95–100 % compliant | Normal |
warning | 85–95 % compliant | Warning |
danger | 70–85 % compliant | Danger |
critical | 0–70 % compliant | Critical |
Spec id: ppe_compliance
Humidity
Unit: % RH
Ambient relative humidity at boilers and loading racks.
Humidity
Unit: % RH
Why monitored
Typical causes
- Weather front
- Steam venting
- Cooling tower drift
Operating ranges
| Band | Range | Label |
|---|---|---|
normal | 20–70 % RH | Normal |
warning | 70–85 % RH | Warning |
danger | 85–95 % RH | Danger |
critical | ≥ 95 % RH | Critical |
Spec id: humidity
Valve State
Unit: % open
Position feedback on ESD, ROV, and critical control valves.
Valve State
Unit: % open
Why monitored
Typical causes
- Actuator failure
- Air supply loss
- Incorrect lineup
Operating ranges
| Band | Range | Label |
|---|---|---|
normal | 0–5 % open | Normal |
warning | 5–15 % open | Warning |
danger | 15–30 % open | Danger |
critical | ≥ 30 % open | Critical |
Spec id: valve_state
Camera Detection
Unit: event score 0–100
AI vision for flame, smoke plume, PPE, and unauthorized vehicle paths.
Camera Detection
Unit: event score 0–100
Why monitored
Typical causes
- Visible flame
- Vapor cloud
- Intrusion
- PPE breach
Operating ranges
| Band | Range | Label |
|---|---|---|
normal | 0–30 event score 0–100 | Normal |
warning | 30–55 event score 0–100 | Warning |
danger | 55–80 event score 0–100 | Danger |
critical | ≥ 80 event score 0–100 | Critical |
Spec id: camera_detection
Wind Speed
Unit: m/s
Anemometer / weather station for dispersion and muster planning.
Wind Speed
Unit: m/s
Why monitored
Typical causes
- Weather change
- Storm front
Operating ranges
| Band | Range | Label |
|---|---|---|
normal | 0–8 m/s | Normal |
warning | 8–15 m/s | Warning |
danger | 15–25 m/s | Danger |
critical | ≥ 25 m/s | Critical |
Spec id: wind_speed